Nemesis Charge Profile

This series of data was taken by hand at discrete points in time. We used a transformer to current limit the wall voltage which was 240V @ 50 Amps, and to limit the current. Our controller allows us to current limit further.

Time

Pack Voltage #1

Pack Voltage #12

Current Charging

Line Voltage

Pack Voltage

Current into Pack

12:40

12.15

11.5

0

0

318

0

12:45

12.6

11.5

16.3

227.5

336

9.7

12:50

12.9

11.5

16.3

227.5

339.2

9.7

12:55

13

12.85

16.3

227.5

340.5

9.7

1:00

13

12.9

16.3

227.5

341.6

9.7

1:05

13.1

12.9

16.3

227.5

342.4

9.7

1:10

13.1

12.9

16.4

227.5

343.4

9.6

1:15

13.1

13

16.4

227.5

344.4

9.6

1:20

15.8

14.2

 

240

383

28.3

1:22

15.8

14.2

39.69

240

383

28.3

1:25

14.2

13.9

40.07

240

369

23.5

1:30

14.2

13.9

32.18

240

370

17.5

1:35

14.1

13.9

24.11

240

371.5

14.2

1:40

15.6

14.3

19.69

240

387.2

11.5

1:42

14.2

13.9

16.39

240

367.7

9.7

1:45

14.1

13.9

13.17

240

370

8.8

1:50

14.2

13.9

 

240

372

7.1

2:00

14.2

13.9

12.52

240

373.8

5.4

2:05

14.2

13.9

7.58

240

373.6

4.2

2:15

14.9

14.4

5.48

240

384.4

3.2

2:20

14.2

13.9

4.67

240

373.4

2.7

2:25

13.5

13.3

3.96

240

353.2

1.6

2:30

13.5

13.4

2.13

240

353.7

1.7

Chart Nemesis Charge Profile


Last Updated on 2/20/98
By Steve E. Sanchez