This series of data was taken by hand at discrete points in time. We used a transformer to current limit the wall voltage which was 240V @ 50 Amps, and to limit the current. Our controller allows us to current limit further.
|
Time |
Pack Voltage #1 |
Pack Voltage #12 |
Current Charging |
Line Voltage |
Pack Voltage |
Current into Pack |
|
12:40 |
12.15 |
11.5 |
0 |
0 |
318 |
0 |
|
12:45 |
12.6 |
11.5 |
16.3 |
227.5 |
336 |
9.7 |
|
12:50 |
12.9 |
11.5 |
16.3 |
227.5 |
339.2 |
9.7 |
|
12:55 |
13 |
12.85 |
16.3 |
227.5 |
340.5 |
9.7 |
|
1:00 |
13 |
12.9 |
16.3 |
227.5 |
341.6 |
9.7 |
|
1:05 |
13.1 |
12.9 |
16.3 |
227.5 |
342.4 |
9.7 |
|
1:10 |
13.1 |
12.9 |
16.4 |
227.5 |
343.4 |
9.6 |
|
1:15 |
13.1 |
13 |
16.4 |
227.5 |
344.4 |
9.6 |
|
1:20 |
15.8 |
14.2 |
|
240 |
383 |
28.3 |
|
1:22 |
15.8 |
14.2 |
39.69 |
240 |
383 |
28.3 |
|
1:25 |
14.2 |
13.9 |
40.07 |
240 |
369 |
23.5 |
|
1:30 |
14.2 |
13.9 |
32.18 |
240 |
370 |
17.5 |
|
1:35 |
14.1 |
13.9 |
24.11 |
240 |
371.5 |
14.2 |
|
1:40 |
15.6 |
14.3 |
19.69 |
240 |
387.2 |
11.5 |
|
1:42 |
14.2 |
13.9 |
16.39 |
240 |
367.7 |
9.7 |
|
1:45 |
14.1 |
13.9 |
13.17 |
240 |
370 |
8.8 |
|
1:50 |
14.2 |
13.9 |
|
240 |
372 |
7.1 |
|
2:00 |
14.2 |
13.9 |
12.52 |
240 |
373.8 |
5.4 |
|
2:05 |
14.2 |
13.9 |
7.58 |
240 |
373.6 |
4.2 |
|
2:15 |
14.9 |
14.4 |
5.48 |
240 |
384.4 |
3.2 |
|
2:20 |
14.2 |
13.9 |
4.67 |
240 |
373.4 |
2.7 |
|
2:25 |
13.5 |
13.3 |
3.96 |
240 |
353.2 |
1.6 |
|
2:30 |
13.5 |
13.4 |
2.13 |
240 |
353.7 |
1.7 |